1 |
Choose Manage→OpenFlow from the NFM-P main menu. The Manage OpenFlow form opens.
|
2 |
Perform one of the following.
-
Create an OpenFlow switch. Perform the following steps.
-
Click Create→OpenFlow switch. The Select Network Element form opens.
-
Select an NE and click OK. The Select Network Element form closes, and the OpenFlow Switch (Create) form opens.
-
Configure the Displayed Name parameter.
-
Click Apply. The form displays additional tabs and status indicators, and the form name changes to OpenFlow Switch (Edit).
-
Configure an existing OpenFlow switch. Perform the following steps. Perform the following steps.
-
Configure the filter criteria and click Search. A list of OpenFlow switches is displayed.
-
Select an OpenFlow switch and click Properties. The OpenFlow Switch (Edit) form opens.
|
3 |
Configure the required parameters.
|
4 |
Define an OpenFlow controller. Perform the following steps.
-
Click on the Controller tab.
-
Click Create. The OpenFlow Controller (Create) form opens.
-
Configure the required parameters.
-
Click OK to save your changes and close the forms.
|
5 |
Repeat
Step 4 to define an additional controller for the switch.
|
6 |
Configure a flow table. Perform the following steps.
-
Click on the Flow Table tab.
-
Click Create, or select an existing flow table and click Properties. The Flow Table (Edit) form opens.
-
Configure the required parameters.
-
Click OK to save your changes and close the forms.
-
To add one or more entries to the flow table, perform
Step 5 to
Step 13 of
To configure an OpenFlow flow table entry .
|
7 |
To configure an embedded IPv4 or IPv6 filter, perform the following steps. Perform the following steps.
-
Click on the Embedded Filter tab.
-
Click Create, or select an existing filter and click Properties. The OpenFlow Embedded IP Filter (Create | Edit) form opens.
-
Configure the required parameters.
-
Choose an ACL IP or IPv6 filter.
-
Click OK to save your changes and close the form.
|
8 |
Close the open forms, as required.
End of steps |