To configure a remote network monitoring policy

Steps
 

Choose Tools→Remote Network Monitoring (RMON) from the NFM-P main menu. The Remote Network Monitoring (RMON) form opens.


Click Create. The RMON (Create) form opens with the General tab displayed.


Configure the required parameters.


Create events to associate with the rising and falling thresholds on the remote NE.

  1. Click on the Events tab.

  2. Click Create. The Event RMON (Create) form opens.

  3. Configure the required parameters.

  4. Click OK. The Event RMON (Create) form closes and the RMON (Create) form reappears.

  5. Repeat 2 to 4 to create another event, if required.


Configure the alarm information to associate with an event you created in Step 4 .

  1. Click on the Alarms tab.

  2. Click Create. The Alarm RMON (Create) form opens.

  3. Configure the required parameters.


Configure the properties for the rising threshold crossing alarm.

  1. Click Select in the Rising TCA Properties panel. The Select Rising Event - Alarm form opens.

  2. Select an event and click OK. The Select Rising Event - Alarm form closes and the Alarm RMON form reappears.

  3. Click Enable and configure the Rising Threshold parameter for the event.


Configure the properties for the falling threshold crossing alarm.

  1. Click Select in the Falling TCA Properties panel. The Select Falling Event - Alarm form opens.

  2. Select an event and click OK. The Select Falling Event - Alarm form closes and the Alarm RMON form reappears.

  3. Click Enable and configure the Falling Threshold parameter for the event.


Click OK. The Alarm RMON form closes and the RMON (Create) form reappears.


Repeat Step 5 to Step 8 to create another alarm, if required.


10 

Click OK to save the policy and close the form, or click Apply to save the policy. See To release and distribute a policy to release and distribute the policy to NEs.


11 

Close the form.

End of steps