To switch to the redundant port for one or more VLL SAPs

Prerequisites
CAUTION 

CAUTION

Service Disruption

Nokia recommends that you set the OLC state of a service to Maintenance before you switch to a redundant port or channel, and reset it to the previous state after the switch is complete. See the NSP System Administrator Guide for more information.

Perform this procedure from a service or site properties form when port redundancy is configured on one or more a Cpipe or Epipe SAPs to:

  • switch to the backup port or channel assigned to the SAP, for example, in the event of a fault on the primary port or channel

  • switch back to the primary port or channel assigned to the SAP, for example, after a fault condition on the primary port or channel is cleared

Note: When multiple SAPs are selected, switching is attempted only for the SAPs that support port redundancy and on which port redundancy is properly configured.

Port redundancy switching fails if the SAP or port is included in one of the following redundancy objects:

  • BGP-MH

  • MC-APS

  • MC-LAG

  • MC-ring

Steps
 

Perform one of the following.

  1. Choose the SAPs from a port properties form:

    1. Choose Manage→Equipment→Equipment from the NFM-P main menu. The Manage Equipment form opens.

    2. Choose Port from the Select Object Type drop-down menu.

    3. Choose the required port and then click Properties. The Physical Port (Edit) form opens.

    4. Click on the L2 Access Interfaces tab.

    5. Choose the required SAPs and then click Properties. The L2 Access Interface (Edit) form opens.

    6. Click on the Port tab.

    7. Go to Step 5 .

  2. Go to Step 2 to choose the SAPs from a service or site properties form.


Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens.


Select the required VLL Cpipe or Epipe service and click Properties. The VLL_type Service (Edit) form opens.


Perform one of the following.

  1. Choose the SAPs from a list of all SAPs in the service.

    1. Click on the L2 Access Interfaces tab. A list of SAPs that are configured on the service is displayed.

    2. Choose the required SAPs.

  2. Choose the SAPs from a list of all of the SAPs on a site.

    1. Expand the Sites object in the service navigation tree.

    2. Click on the site object. The Site (Edit) form opens.

    3. Click on the Interfaces tab.

    4. Click on the L2 Access Interfaces tab. A list of all SAPs on the site is displayed.

    5. Choose the required SAPs.


Click Switch to Redundant SAP. A dialog box appears.


Click OK. The selected SAPs in the list are deleted, and new SAPs are created on the redundant port.


To confirm the redundancy status of a SAP:

  1. Choose the SAP in the list and click Properties. The Port (Edit) form opens.

  2. Click on the Port tab. The Manual Switch Backup State indicator displays one of the following:
    • Backup SAP in Use, if you switch from primary to backup

    • Backup Port Specified, if you switch from backup to primary

    Note:

    When the Manual Switch Backup State indicator reads Backup SAP in Use, the displayed port redundancy information is for the primary port of the SAP, and is read-only.


Close the forms.

End of steps