To configure LI on a specific NAT subscriber
Steps
1 |
Choose Manage→Service→Mirror Services from the NFM-P main menu. The Manage Mirror Services form opens. |
2 |
Choose a mirror service and Properties. The Mirror Service Name (Edit) form opens. |
3 |
Click on the Sites tab. A list of mirror service sites are displayed. |
4 |
Choose a site and click Properties. The Mirror Site (Edit) form opens. |
5 |
Click on the LI NAT Sources tab. Note: The LI NAT Sources tab appears only if the Encapsulation Type parameter for the mirror site is set to Ethernet and the L3 encapsulation Header Type parameter is set to IP-UDP Shim. See To configure Layer 3 encapsulation on a source site to allow LI-mirrored packets to be placed into a routable header for more information about how to set the Header Type parameter. |
6 |
Click Configure LI Source Configuration. |
7 |
Click on the Ethernet Header tab. |
8 |
Configure the required parameters. |
9 |
Click on the L2 Aware Subscribers tab. |
10 |
Click Create. The LI Source NAT L2 Aware Subscriber (Create) form opens. |
11 |
Configure the required parameters. |
12 |
Click OK. The LI Source NAT L2 Aware Subscriber (Create) form becomes a tab. |
13 |
Click OK. The LI Source NAT L2 Aware Subscriber (Create) tab closes and the Mirror Service (Edit) form reappears with the Sites tab displayed. |
14 |
Choose a site and click Properties. The Mirror Site (Edit) form opens. |
15 |
Click on the LI NAT Sources tab. The Ethernet Header tab is displayed. |
16 |
Click on the Dual Stack Lite LSN Subscribers tab. |
17 |
Click Create. The LI Source Dual Stack Lite LSN Subscriber (Create) form opens. |
18 |
Configure the required parameters. |
19 |
Click OK. The LI Source Dual Stack Lite LSN Subscriber (Create) form becomes a tab. |
20 |
Click OK. The LI Source Dual Stack Lite LSN Subscriber (Create) tab closes and the Mirror Service (Edit) form reappears with the Sites tab displayed. |
21 |
Choose a site and click Properties. The Mirror Site (Edit) form opens. |
22 |
Click on the LI NAT Sources tab. The Ethernet Header tab is displayed. |
23 |
Click on the Classic LSN Subscribers tab. |
24 |
Click Create. The LI Source Classic LSN Subscriber (Create) form opens. |
25 |
Configure the required parameters. |
26 |
Click OK. The LI Source Classic LSN Subscriber (Create) form becomes a tab. |
27 |
Click OK. The LI Source Classic LSN Subscriber (Create) tab closes and the Mirror Service (Edit) form reappears with the Sites tab displayed. |
28 |
Click on the NAT 64 LSN Subscribers tab. |
29 |
Click Create. The LI Source NAT 64 LSN Subscriber (Create) form opens. |
30 |
Configure the required parameters. |
31 |
Click OK. The LI Source NAT 64 LSN Subscriber (Create) form becomes a tab. |
32 |
Click OK. The LI Source NAT 64 LSN Subscriber (Create) tab closes and the Mirror Service (Edit) form reappears with the Sites tab displayed. |
33 |