To configure learning protection parameters on a VPLS SDP binding
Purpose
This procedure applies to MFIB, STP, FIB, MRP, and MAC learning protection parameters on a VPLS SDP binding.
Note: The single-slot models of the 7450 ESS and 7750 SR support the addition or deletion of MFIB allowed daughter cards.
The MFIB Allowed Daughter Card tab does not appear if you are creating a Mesh SDP binding for a B-site.
Steps
1 |
Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens. |
2 |
Choose a VPLS and click Properties. The VPLS Service (Edit) form opens. |
3 |
On the service tree, expand Sites→site→Mesh|Spoke SDP Bindings. |
4 |
Right-click on the mesh or spoke SDP binding you need to configure and choose Properties. The [Mesh|Spoke] SDP Binding (Edit) form opens. |
5 |
Click on the Forwarding Control tab. |
6 |
Perform the following if you are configuring a spoke SDP binding. Otherwise, go to Step 7 .
|
7 |
If you are configuring a mesh SDP binding, click on the FIB tab and configure the parameters. Otherwise, go to Step 8 . |
8 |
Click on the MFIB Allowed Daughter Card tab and click Create. The SDP Binding MFIB Allowed Daughter Card (Create) form opens. |
9 |
Select a daughter card, save the changes and close the form. |
10 |
Click on the MRP tab if you are configuring a mesh or spoke SDP binding for a B-site and configure the parameters. Otherwise, go to Step 12 . Note: The MRP tab does not appear if you are creating an SDP binding for an I-site. |
11 |
Select an PBB MRP Policy. |
12 |
Save the changes and close the forms. End of steps |