To create a MEP on a VPLS SDP binding
Steps
1 |
Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens. |
2 |
Choose a VPLS and click Properties. The VPLS Service (Edit) form opens. |
3 |
On the service tree, expand Sites→site→Mesh|Spoke SDP Bindings. |
4 |
Right-click on the mesh or spoke SDP binding you need to configure and choose Properties. The [Mesh|Spoke] SDP Binding (Edit) form opens. |
5 |
Click on the OAM tab, then the ETH-CFM tab. |
6 |
Configure the Enable Virtual MEP Filter parameter in the Virtual MEPs panel. |
7 |
Configure the parameters in the Squelch Ingress Level panel. Levels must be assigned contiguously from Level 0. If you select a level greater than 0, then all levels lower than the one you chose will automatically be selected. The Squelch Ingress Levels configured for all the mesh or spoke bindings on a site can be compared in one view when you click on the Mesh SDP Bindings or Spoke SDP Bindings item below a site on the navigation tree. Use the scroll bar to locate the Squelch Ingress Level columns. |
8 |
Configure the parameters on the LMM Session Stats Collection panel as required. |
9 |
To create a MEP:
|
10 |
To add a MIP to the SDP binding, perform To create a MIP on a VPLS SDP binding . |
11 |
Save the changes and close the forms. End of steps |