To configure OAM components on a VPRN site
Steps
1 |
Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens. |
2 |
Choose a VPRN service and click Properties. The VPRN Service (Edit) form opens. |
3 |
On the service navigation tree, expand the Sites icon, right-click on a routing instance and choose Properties. The VPRN Site (Edit) form opens. |
4 |
Click on the OAM tab, then on the ETH-CFM tab. |
5 |
Configure the Tunnel Fault Notification parameter in the Facility MEPs panel. This parameter must be set to Accept, in order to receive the fault notification from a tunnel facility MEP. Tunnel Fault Notification is configurable on sites where the device has ports configured in access or hybrid mode with QinQ encapsulation. |
6 |
Click the OAM tab, then the Configuration tab. |
7 |
Configure the required Test Generation Options parameters. |
8 |
Click the OAM tab, then the TWAMP tab. |
9 |
To add a TWAMP reflector to this site, perform To create a TWAMP Light reflector on a VPRN site . |
10 |
Save the changes and close the forms. End of steps |