To configure an L3 access interface on a VPRN site
Steps
1 |
Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens. |
2 |
Choose a VPRN service and click Properties. The VPRN Service (Edit) form opens. |
3 |
On the service navigation tree, expand the Sites icon, right-click on a routing instance and choose Properties. The VPRN Site (Edit) form opens. |
4 |
Right-click on L3 Access Interfaces and choose Create VPRN L3 Access Interface or expand L3 Access Interfaces, right-click on an access interface and choose Properties. The VPRN L3 Access Interface (Create|Edit) form opens. |
5 |
Configure the required parameters. If you enable the Loopback Enabled parameter, you cannot associate a port with the L3 access interface. The Admin Link Local Address parameters are only configurable when the IPv6 Allowed parameter is enabled. The Unnumbered Type parameter is configurable when the Class parameter is set to Unnumbered. The Unnumbered IP Address parameter is configurable when the Unnumbered Type parameter is set to IP Address. The Unnumbered Interface Name parameter is configurable when the Unnumbered Type parameter is set to Name. IPv6–specific parameters are only configurable when the IPv6 Allowed parameter is enabled. The Tunnel Fault Notification parameter is configurable on interfaces where the device has ports configured in access or hybrid mode with QinQ encapsulation. If you are configuring a tunnel facility MEP, Tunnel Fault Notification must be set to Accept, in order to receive the fault notification from the tunnel facility MEP. |
6 |
Configure the required parameters in the Frame Size Constraints panel. |
7 |
Configure the required parameters in the Unicast RPF panel. |
8 |
Select a host lockout policy in the Host Lockout panel. |
9 |
Configure the required parameters in the PTP HW panel. You can only enable the PTP HW Assist parameter after the port is associated to the interface, and an IP address is configured on the interface. |
10 |
To configure Cflowd sampling:
|
11 |
Configure the required parameters in the Redundant Next Hop Addresses panel. |
12 |
Select a monitored group in the Operational Group panel. |
13 |
Associate a port with the L3 access interface:
|
14 |
Save the changes and close the forms. End of steps |