To configure a cellular port on a 7705 SAR-Hm

Before you begin

SIM cards must be installed in the 7705 SAR-Hm before the cellular ports can be configured.

Steps
 

On the equipment tree, expand Network→7705 SAR-Hm→Shelf→Card Slot 1→Daughter Card Slot 1→Port 1/1/1.


Right-click on the Port icon and choose Properties. The Physical Port (Edit) form opens.


Configure the required general parameters.

The Mode and Encapsulation Type parameters are set to Network and Cellular, respectively, by default. These parameters cannot be changed.


Click on the States tab and configure the required parameters.


Click on the Cellular tab and configure the required parameters.

  1. A PDN profile must be configured. See Chapter 69, PDN profile policies for more information.

  2. To configure SIM switchover behaviour, click on the SIM Cards tab and configure the required parameters.

    The length of time configured for the Fail Duration (Min) parameter specifies when to perform an automatic failover from one SIM to the other. Set the Fail Duration (Min) parameter to a value lower than the Down Recovery Interval (Min) parameter on the cellular MDA, or a node reboot will happen instead of a SIM switchover.

  3. View port bearer and port traffic flow template details by performing the following:

    • Click on the PortBearer tab, select a bearer in the list, and click Properties. The Cellular Port Bearer form opens.

    • Click on the PortTFT tab, select a traffic flow template from the available list, and click Properties. The Port Traffic flow Template (TFT) form opens.

  4. To enable the 7705 SAR-Hmc to operate as a CBSD category A/B device in the CBRS spectrum band, click on the CBSD tab and configure the required parameters.


Click on the Statistics tab and perform one of the following:

  1. Click Collect to collect performance statistics data on demand. The collected statistics are listed on the form.

  2. Click Collect All to collect one on-demand statistics record for each statistic type that the object supports. The collected statistics are listed on the form.


Save your changes and close the form.

End of steps