To configure a redundant VLAN range on a VPLS L2 access interface

Purpose

Configure a redundant VLAN range.

Note: If an MVPLS site has SAPs that manage traffic on the associated VPLS SAPs, you must define a redundant VLAN range during SAP creation. The redundant VLAN range defines the range of VC IDs for VPLS SAPs that the MVPLS manages.

Steps
 
1 

Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens.


2 

Choose a VPLS and click Properties. The VPLS Service (Edit) form opens.


3 

On the service tree, expand Sites→site→L2 Access Interfaces.


4 

Right-click the L2 access interface and choose Properties. The VPLS L2 Access Interface (Edit) form opens.


5 

Click on the Redundancy tab and click Create. The RedundantVlanRange (Create) form opens.


6 

Configure the required parameters.


7 

Save the changes and close the forms.