To force a switchover to a redundant spoke SDP binding

Prerequisites

This procedure can only be performed on a VPLS that has been configured with endpoints that are associated redundant spoke SDP bindings.

Steps
 
1 

Choose Manage→Service→Services from the NFM-P main menu.


2 

Choose the required VPLS and click Properties. The VPLS Service (Edit) form opens.


3 

On the service tree, expand the site on which you want to perform the switchover.


4 

Right-click on the redundant spoke SDP binding under an endpoint for the site for which you want to perform the switchover and choose Force Switchover.


5 

You can clear the switchover at a later time by performing Step 1 to Step 4 again and selecting the Clear Forced Switchover.

Note: You must clear a manually forced switchover by using the Clear Forced Switchover button when the active spoke SDP binding is restored. The NFM-P cannot automatically switch to another active spoke SDP binding if this is not done.


6 

Close the forms.

End of steps