To retrieve I&C files stored by Wavence Release 22 or earlier devices using the NFM-P

Prerequisites

Use this procedure to retrieve I&C files stored on MSS-4/8 Wavence devices, Release 22 or earlier. For devices using Release 23A or later, see To retrieve I&C files stored by Wavence Release 23A or later devices using the NFM-P.

Steps
 

Choose Administration→NE Maintenance→I&C Parameters Retrieval. The I&C Parameters Retrieval window opens.


Click Search. The I&C Parameters Retrieval Status window lists the Wavence nodes. Click the Retrieve Radio RSL button and click Yes on the confirmation window.


The RSL File Retrieval Status column is updated with the retrieval status, which is limited to one of the following:

  • If the CLI login credentials on the NE does not match the login credentials in CLI panel of the read and write mediation policy, an “Authentication failed” message is displayed.

  • If there are no RSL CSV files on the NE, an "RSL Files does not exist on NE" message is displayed. File generation is performed using the WebCT interface.

  • If there is an RSL CSV file for a radio port on the NE, the file is retrieved and the RSL status is updated.

End of steps