1   | 
 In the Network Map and Health, Current Alarms view, click the More button   and select Settings. The Alarm Settings form opens. 
  | 
2   | 
 Click Current Alarms on the left-hand panel. 
  | 
3   | 
 Enable the Aging Settings option and specify the number of days after which alarms are deleted. 
  | 
4   | 
 Under Overflow Settings, specify the percentage of the maximum alarm count at which an alarm overflow warning is issued. 
Note: The maximum count for alarms from sources other than the NFM-P is 250 000 if the WS-NOC and NSP are integrated, or 300 000 if the WS-NOC is deployed as an independent system. 
  | 
5   | 
 Specify an overflow action. If you choose Halt, all new alarms are dropped. If you choose Wrap, alarms are purged from the database, based on the following settings: 
  | 
6   | 
 Save your changes. 
End of steps  |