To verify the FIB configuration

Purpose

This procedure describes how to verify the connectivity of customer equipment on the service tunnel.

Steps
 
1 

Click on the L2 Access Interfaces tab on the Services (Edit) form. A list of L2 access interfaces appears.


2 

Double-click on a row in the list. The L2 Access Interface form appears.


3 

Click on the Forwarding Control tab.


4 

Click on the FIB Entries tab.


5 

Click Resync.

  1. If there is a list of FIB entries, confirm the number of entries with the customer configuration requirement. If the configuration meets the customer requirement, go to Stage 5 in Workflow to troubleshoot a service or connectivity problem.

  2. If there are no FIB entries, there is a configuration problem with the customer equipment or the connection from the equipment to the service tunnel.

    1. Confirm that the NFM-P service configuration aligns with the customer requirements.

    2. Confirm that there are no problems with the customer equipment and associated configuration.


6 

If the service problem persists, another type of service problem may be present. Perform the steps of the Workflow to troubleshoot a service or connectivity problem troubleshooting workflow.


7 

If the workflow does not identify the problem with your service, contact your technical support representative; see Chapter 1, NSP troubleshooting overview.

End of steps