To configure an IEEE 1588 PTP clock on a 7705 SAR

Before you begin

You can only configure the IEEE 1588 PTP clock on a 7705 SAR that is configured as an IEEE 1588 PTP client. See To configure timing synchronization for information about how to configure the NE as a PTP client.

Steps
 
1 

On the equipment tree, expand Network→NE.


2 

Right-click on the NE and choose Properties. The Network Element (Edit) form opens.


3 

Click on the IEEE PTP Clock tab and click Create. The IEEE 1588 PTP Clock (Create) form opens.


4 

Configure the required parameters.

If you set the PTP Profile to ITU-T G.8275.1 or ITU-T G.8275.2, the Clock Local Priority parameter is configurable.

You can configure the IEC/IEEE 61850.9.3 and the C37.238-2017 PTP clock only on a 7705 SAR with a CSM clock ID. Master clock is only supported for 7705 SAR devices with integrated GNSS. When you configure a 7705 SAR with the IEC/IEEE 61850.9.3 or the C37.238-2017 profile, the default settings are automatically applied.


5 

Select a clock MDA for the PTP clock.


6 

Select a source interface for the PTP clock.


7 

If you are configuring a 7705 SAR-8 or 7705 SAR-18, you can view the properties of the local clocks, active or standby, in the Local Clock-Active/Standby panel.


8 

If you set the Clock Type parameter to Boundary or Ordinary, Slave, you can view the Parent clock information in the Parent Clock panel.


9 

Click Apply to save your changes.


10 

To turn up PTP ports on the IEEE 1588 PTP clock:

  1. Click on the IEEE PTP Port tab, and click Create. The IEEE 1588 PTP clock (Create) form opens.

  2. Select a port and configure the required parameters.

    The Cfg Sync Rate parameter is not supported if the Clock Type parameter was configured as Ordinary, Slave in Step 4 .

    You can only configure the Local Priority and Master Only parameters if the PTP Profile parameter was configured as ITU-T G.8275.1 or ITU-T G.8275.2 in Step 4 .

  3. Save your changes.


11 

Save your changes and close the forms.

End of steps