To inventory the port types of one NE

Steps
 
1 

Choose Manage→Equipment→Equipment from the NFM-P main menu. The Manage Equipment form opens.


2 

Choose Network Element (Network) from the object drop-down menu and click Search. A list of NEs is displayed.


3 

Select an NE in the list and click Properties. The Network Element (Edit) form opens.


4 

Click on the Inventory tab and choose Port (Physical Equipment) from the object drop-down menu. A list of ports is displayed.


5 

To display more detailed port inventory information, expand the Port (Physical Equipment) object and choose from the available objects.


6 

Sort the inventory output. See To list and sort equipment information .


7 

Save the inventory output. See To save an inventory list .


8 

Close the forms.

End of steps