To create a spoke SDP FEC binding on a VLL Epipe site

Steps
 
1 

Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens.


2 

Choose a VLL service and click Properties. The Epipe Service (Edit) form opens.


3 

On the service tree, expand Sites→Spoke SDP FECs, right-click and choose Create Spoke SDP FEC. The Spoke SDP FEC (Create) form opens.


4 

Configure the required general parameters.


5 

In the Source panel, select an SAII address.


6 

In the Target panel, configure the Auto Config parameter or select a TAII address.


7 

In the General Parameters panel:

  1. Configure the parameters.

  2. Select a path.


8 

In the Redundancy panel:

  1. Select an endpoint.

  2. Configure the parameters.


9 

In the Pseudowire Signaling panel, configure the Enable PW Standby Signaling Slave parameter.


10 

Save the changes and close the forms.

End of steps