To configure Ethernet loopback for a VLL Epipe L2 access interface on a 7705 SAR

Purpose

Perform this procedure to configure OAM loopback for an Epipe SAP on a 7705 SAR NE. You can perform individual loopback tests, or enable loopback as part of Y.1564 test configuration. See STM Y.1564 test configuration for more information about Y.1564 tests.

Steps
 
1 

Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens.


2 

Choose an Epipe service and click Properties. The Epipe Service (Edit) form opens.


3 

On the navigation tree, expand the 7705 SAR site, then right-click on the required L2 access interface and choose Properties. The properties form for the SAP opens.


4 

Click on the Ethernet Loopback tab.


5 

Configure the required parameters.

If you are configuring Ethernet loopback for Y.1564 tests, set the Mode parameter to Internal, and enable the Mac Swap parameter.


6 

Save the changes and close the forms.

End of steps