To run an OAM validation test for a VLL service

Prerequisites

An OAM validator test suite must be created for the tested entity. See Chapter 89, Service Test Manager for more information about how to create a validator test suite.

Note: As an alternative, you can also run an OAM validation test on the service by performing a One Time Validation. This is a mostly automated procedure and is described in To run a one-time validation test on a service .

Steps
 
1 

Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens.


2 

Choose a service and click Properties. The VLL Type_of_VLL (Edit) form opens.


3 

Click Validate. If an OAM validator test suite is not associated to the service, a dialog box appears:

  1. Click OK to associate the service with an existing OAM validator test suite.

  2. Select an OAM validator test suite.


4 

View the State Cause indicators. When the validation test fails, a check mark appears beside the OAM Validation Failure indicator.


5 

Click on the Tests tab. The Test Suite tab is displayed.


6 

Click on the Tested Entity Result tab.


7 

Choose an entry and click Properties. The Tested Entity Result (Edit) form opens.


8 

Click on the Results tab to display the validation test results.


9 

If you need to compare two test results from the same type of test, choose the two test results and click Compare; the Difference form opens. Otherwise, go to Step 12 .


10 

Compare the test results.


11 

Close the Difference form.


12 

Close the forms.

End of steps