To view the VPLS operational status

Steps
 

Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens.


Choose a VPLS and click Properties. The VPLS Service (Edit) form opens.


View the Aggregated Operational State and State Cause indicators. When the Aggregated Operational State is Down or Partially Down, a check mark beside the appropriate State Cause indicator identifies the type of associated service fault.


Click on the appropriate tab to view or edit an object that is identified as faulty by a State Cause indicator.


Click on the Faults tab to view the alarms for the object. The Object Alarms tab is displayed.


Click on the Aggregated Alarms tab to view the aggregated alarms for the object.


Click on the Tests tab if the OAM Validation Failed indicator is enabled. You can view the OAM validation test suite results by clicking on the Tested Entity Result tab.

Note: You can run the OAM Validation test suite for this service from this form by clicking on the Validate button. If the Validate button is not visible, click on the More Actions button and choose Validate.

As an alternative, you can also run an OAM validation test on the service by performing a One Time Validation.


Save the changes and close the forms.

End of steps