How do I configure an NFM-P analytics rule?

Purpose

Perform this procedure to enable or disable raw data collection, and to specify data retention, for a statistics class to be processed using NFM-P analytics. Raw data collection is enabled by default for each statistics class.

Steps
 

Choose Tools→Analytics→AA Collection Manager from the NFM-P main menu. The AA Collection Manager form opens with a list of analytics rules displayed.


Select the required analytics rule and click Properties. The Analytics Rule (Edit) form opens.


Select the Collection Enabled parameter.


Configure the Raw Data Retention Time (days) parameter.


Close the AA Collection Manager form.

End of steps