Configuring SROS
Description
The SROS section of the NSP configuration file is used to integrate an NSP deployment and an SROS VM such as the VSR-NRC in order to use the NSP PCE functions.
sros — required when integrating NSP with an SROS VM | ||
enabled |
Whether path computation using SROS VM is enabled Default: false Note: When set to true, the SROS block of the hosts file must be configured. | |
partialSync |
Whether partial sync functionality is enabled Default: true | |
ip |
IP address of SROS VM | |
router_id |
SROS VM router ID | |
matePort |
The port used by SROS VM to communicate with other SROS VM in HA configuration Default: 4199 | |
global |
Whether global is enabled | |
pcep |
Whether PCEP is enabled Default: false | |
rom |
Whether rom is enabled | |
bgpls |
Whether BGP LS is enabled Default: false | |
vms |
ip |
IP address of SROS VM |
router_id |
SROS VM router ID | |
v_id |
SROS VM virtual ID; must be an integer value NOTE: The value must be the same for redundant VMs. | |
mateAddress |
The address used by SROS VM to communicate with other SROS VM in HA configuration Default: the IP of the other SROS VM within the same vId cluster | |
matePort |
The port used by SROS VM to communicate with other SROS VM in HA configuration Default: 4199 | |
global |
Whether global is enabled | |
pcep |
Whether PCEP is enabled Default: false | |
rom |
Whether rom is enabled | |
bgpls |
Whether BGP LS is enabled Default: false |