To perform an NE resync audit

Steps
 

Choose Equipment from the navigation tree view selector. The managed NEs are displayed.


Right-click on an NE and choose NE Resync Audit.


Enable the check box if you want to include read-only attributes in the audit and click Yes. The NE Audit Result form appears and displays the NE Audit State as “in progress”.

Note: The NFM-P displays an error message and does not begin the resync audit if the NE in unreachable.


When the audit completes, choose one of the following based on the NE Audit State:

  1. If the NE Audit State displays “succeeded” and the NE Audit Result displays “misaligned”, go to Step 5 .

  2. If the NE Audit State displays “succeeded” and the NE Audit Result displays “aligned”, then no further action is required.

  3. If the NE Audit State displays “failed”, information about the failure is displayed in the Error Messages panel. Click to expand the panel.


Click Show Difference. The Show Difference form opens with a list of difference entries displayed.


To resync a missing or added object, perform a full resync.


To resync a property change for a single object with the NFM-P:

  1. Select a difference entry from the list. The panes at the bottom of the form display the misaligned data for the entry.

  2. Click Properties for the SAM Object. The Properties form of the object is displayed.

  3. Click Resync.

  4. Click Yes and wait for the object to resync with the NFM-P. The value of the misaligned parameter changes if the resync operation is successful.


To save the results of the resync audit to an HTML or CSV file:

  1. Right-click on a column header in the differences list and choose Save to File. The Save As form is displayed.

  2. Navigate to the required location on the client workstation and specify a file name.

  3. Choose a file type and click Save.


Close the forms.

End of steps