Problem: All SNMP traps from managed devices are arriving at one NFM-P server, or no SNMP traps are arriving
Configuration for SNMP trap notifications
When you install the NFM-P, you specify the port on which SNMP traps arrive.
In addition, the following configuration is required for SNMP trap notifications to work:
-
Enable the SNMP parameters on the devices before managing them.
-
Ensure that a unique trapLogId is specified for each router to communicate with the NFM-P.
Note: You must have sufficient user permissions, for example, admin permissions, to configure SNMP on a device.
Steps
1 |
See the commissioning chapter of the NSP NFM-P Classic Management User Guide for more information about configuring devices for NFM-P management. |
2 |
Configure SNMP on the device using CLI. End of steps |