| 1  | Choose Manage→Redundancy→Node Redundancy from the NFM-P main menu. The Manage Node Redundancy form opens. 
 | 
| 2  | Choose MC Peer Group (Multi-Chassis) and click Search. 
 | 
| 3  | Select an MC peer group and click Properties. The MC Peer Group (Edit) form opens. 
 | 
| 4  | Click on the Associated Groups tab. 
 | 
| 5  | Right-click on the MC Lag object in the navigation tree and choose Create MC LAG Group. The MC LAG Group (Create) form opens. 
 | 
| 6  | Configure the required parameters. The LACP Key, System ID, and System Priority parameters must be left at the default when the Standby Signalling parameter is set to Power Off. 
 | 
| 7  | Configure the Use LACP Key and MAC LSB (hex) parameters. Note: The parameters are configurable only on the 7750 SR, 7750 SR-c12, 7750 SR-12E, 7450 ESS, and 7950 XRS. The NE must also be configured with an IOM 3 MDA or an XMA. The parameters are displayed and configurable only when both MC LAG members are PBB-capable. 
 | 
| 8  | Choose the LAG for the first MC LAG member in the First Site panel. Note: If you are configuring access dual homing with local switching over PBB tunnels, the L2 access interfaces must be on LAGs that participate in the MC LAG. 
 | 
| 9  | Choose the LAG for the second MC LAG member in the Second Site panel. 
 | 
| 10  | Save your changes and close the forms. End of steps |