To configure scheduling on an L2 access interface
Steps
| 1  | Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens. | 
| 2  | Configure the filter criteria and click Search. A list of services appears. | 
| 3  | Choose a VPLS and click Properties. The VPLS Service (Edit) form opens. | 
| 4  | On the service tree, expand Sites→site→L2 Access Interfaces. | 
| 5  | Right-click the L2 access interface and choose Properties. The VPLS L2 Access Interface (Edit) form opens. | 
| 6  | Click on the Schedulers tab and configure the required parameters. Note: The Schedulers tab is configurable only if a port is assigned to the interface. | 
| 7  | To configure scheduling on a 7210 SAS site, enable and configure the required parameters in the Egress Aggregate Rate Limit panel and go to Step 30 . | 
| 8  | To configure scheduling on a 7705 SAR site: Note: For the 7705 SAR, scheduler behavior is determined by the scheduler mode, which is 4-Priority by default. You can only configure the Egress and Ingress Aggregate Rate Limit parameters when the Scheduler Mode parameter is set to 16-Priority. You can set the Scheduler Mode to 16-Priority only when the port is on an MDA that supports 16-Priority. See the 7705 SAR documentation for more information. If you change the Scheduler Mode parameter from 16-Priority to 4-Priority, the NFM-P automatically restores the default settings for the Egress Aggregate Rate Limit and Ingress Aggregate Rate Limit panels when you Apply your changes. 
 | 
| 9  | To apply an aggregation scheduler policy to the interface: Note: You cannot specify an access scheduler policy if the port you selected To create a VPLS or MVPLS L2 access interface is an HSMDA port. Go to Step 30 . 
 | 
| 10  | To specify that an aggregation scheduler policy is not being applied to the interface, set the Aggregation parameter to Off. Note: The Aggregation parameter is not configurable if the port you selected in To create a VPLS or MVPLS L2 access interface is an HSMDA port. | 
| 11  | Select an ingress scheduler in the Ingress Scheduler panel to choose an ingress scheduler. | 
| 12  | Configure the required parameters. The Aggregate Rate Limit (kbps), Frame-Based Accounting, and Limit Unused Bandwidth parameters are configurable only when there is no scheduler specified in the Egress Scheduler panel. The Frame-Based Accounting parameter is not configurable if the port you selected in To create a VPLS or MVPLS L2 access interface is an HSMDA port. You cannot specify an egress scheduler when the Aggregate Rate Limit (kbps) parameter is set to a value greater than zero. | 
| 13  | Select an ingress policer control policy in the Ingress Policer Control Policy panel. | 
| 14  | Click Create in the Ingress Policer Control Override panel. The Ingress Policer Control Override (Create) form opens. | 
| 15  | Configure the required parameters. | 
| 16  | Click the Level Override Policy Items tab. | 
| 17  | Select an item from the list and click Properties. The Ingress Policy Policer Level Override form opens. | 
| 18  | Click the Override tab. | 
| 19  | Configure the override for the Maximum Cumulative Buffer Space (bytes) parameter. | 
| 20  | Close the forms. | 
| 21  | If the port you selected in To create a VPLS or MVPLS L2 access interface is an HSMDA port, go to Step 30 . | 
| 22  | Select an egress scheduler in the Egress Scheduler panel. | 
| 23  | Select an egress policer control policy in the Egress Policer Control Policy panel. | 
| 24  | Click Create in the Egress Policer Control Override panel. The Egress Policer Control Override (Create) form opens. | 
| 25  | Configure the required parameters. | 
| 26  | Click the Level Override Policy Items tab. | 
| 27  | Select an item from the list and click Properties. The Egress Policy Policer Level Override form opens. | 
| 28  | Click the Override tab. | 
| 29  | Configure the override for the Maximum Cumulative Buffer Space (bytes) parameter. | 
| 30  | Save the changes and close the forms. End of steps |