To create and run a VCCV trace OAM diagnostic from a dynamic PW to a static PW segment from the STM
Steps
You can perform this test from a VPLS/MVPLS or VLL service form, or from the service flat topology map.
| 1  | Choose Tools→Service Test Manager (STM) from the NFM-P main menu. The Service Test Manager form opens. | 
| 2  | Click Create and choose Service→VCCV Trace. The VCCV Trace (Create) form opens. | 
| 3  | Configure the required parameters. | 
| 4  | Set the Test Type parameter in the Test Object panel to Regular. | 
| 5  | Select the required spoke or mesh SDP binding in the First Spoke/Mesh SDP Binding panel. Note: The selection of spoke bindings is applicable to both VPLS and VLL services; mesh bindings are only applicable to VPLS and MVPLS. However, when creating this test for MVPLS and VPLS, the concept of downstream spoke SDP bindings does not apply. | 
| 6  | To configure this test for a VLL, select the required downstream spoke SDP binding in the Downstream SDP Binding panel. | 
| 7  | Set the FEC Type parameter to Static. | 
| 8  | Configure the required parameters in the Test Multi-Segment PW (Static) panel for the dynamic PW. | 
| 9  | Click on the Test Parameters tab and configure the required parameters. The Probe History parameter is only configurable when the NE Schedulable parameter is enabled. If you are configuring a VCCV trace test for a VLL with a switching site, you must set the Reply Type parameter to IP. | 
| 10  | Click on the Results Configuration tab and configure the Required parameters. | 
| 11  | Save the changes and close the forms. | 
| 12  | To run the OAM diagnostic test and view the results, perform To run one or more OAM diagnostic tests from the STM and view the test results . See To interpret OAM diagnostic test results on the STM for information about how to interpret the test results. End of steps |