To create and run a MPLS LSP trace OAM diagnostic test from the STM
Steps
The MPLS LSP Trace OAM diagnostic test is supported on both IPv4 and IPv6 source and destination addresses.
| 1  | Choose Tools→Service Test Manager (STM) from the NFM-P main menu. The Service Test Manager form opens. | 
| 2  | Click Create and choose MPLS→LSP Trace. The LSP Trace (Create) form opens. | 
| 3  | Configure the required parameters. The available parameters change depending on the option specified for the Target Type parameter. Information about NFM-P parameters is available in the XML API Reference. | 
| 4  | Click on the Test Parameters tab and configure the required parameters. The Probe History parameter is only configurable when the NE Schedulable parameter is enabled. | 
| 5  | Click on the Results Configuration tab and configure the required parameters. | 
| 6  | As required, click on the NM Thresholds tab to configure threshold-crossing alarms. Note: The NM Thresholds tab will only be displayed and configurable when the NE Schedulable parameter is not enabled. See To configure threshold-crossing alarms or NM threshold-crossing alarms for an OAM diagnostic test or STM test policy for more information. | 
| 7  | Save the changes and close the forms. | 
| 8  | To run the OAM diagnostic test and view the results, perform To run one or more OAM diagnostic tests from the STM and view the test results . See To interpret OAM diagnostic test results on the STM for information about how to interpret the test results. End of steps |