| 1  | Create an FPE on the NE, with an SPD ID range configured and VXLAN termination enabled. See 
To create an FPE 
 | 
| 2  | Create a VXLAN tunnel termination: 
On the equipment tree, right-click on an NE and choose Properties. The Network Element (Edit) form opens.
Click on the Globals tab, then the Service sub-tab, then the VXLAN sub-tab, then the Tunnel Termination sub-tab. 
Enter the tunnel termination IP address. The address must be a loopback interface address and a non-system IP address.
In the FPE panel, click Select and choose the FPE ID created in the previous step.
Click Apply and close the form. 
 | 
| 3  | Create a VPLS Site. See 
To configure a VPLS site.  In the VXLAN Tunnel End Point panel, click Select and choose the VXLAN tunnel termination created in the previous step. 
 | 
| 4  | Create a system interface with an IPv4 address at the NE routing instance. See 
To create an L3 network interface on a routing instance. 
 | 
| 5  | Configure the assisted replication IP address with the address configured in the previous step.  
On the equipment tree, right-click on an NE and choose Properties. The Network Element (Edit) form opens.
Click on the Globals tab, then the Service sub-tab, then the General sub-tab. 
Click Select and choose the interface created in the previous step, or enter the IP address of the interface.  
 | 
| 6  | Create a VXLAN identifier at the VPLS service: 
Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens.
Choose a VPLS service and click Properties. The VPLS Service (Edit) form opens.
Click on the BGP sub-tab, then the EVPN sub-tab. 
Configure the parameters in the VXLAN panel.  To configure the Assisted Replication type parameter as Replicator, step 
Step 5 must be completed. End of steps |