To create and run a BIER trace OAM diagnostic test from the STM

Steps
 
1 

Choose Tools→Service Test Manager (STM) from the NFM-P main menu. The Service Test Manager form opens.


2 

Click Create and choose Multicast→BIER Trace. The BIER Trace (Create) form opens.


3 

Configure the required parameters on the General tab.


4 

Select a source site in the Site panel.


5 

Depending on the option selected for the BIER Target Type parameter in Step 3, perform one of the following:

  1. For the BFR ID option:

    1. Configure the Sub-Domain ID parameter.

    2. Select a destination BFR ID in the BFR ID panel.

      The BFR ID must be in the configured sub-domain.

  2. For the BFR Prefix option:

    1. Configure the Sub-Domain ID parameter.

    2. Select a destination prefix in the BFR Prefix panel.

      The BFR prefix must be in the configured sub-domain.


6 

Click on the Test Parameters tab and configure the required parameters.


7 

Click on the Results Configuration tab and configure the required parameters.


8 

Save the changes and close the forms.


9 

To run the OAM diagnostic test and view the results, perform To run one or more OAM diagnostic tests from the STM and view the test results . See To interpret OAM diagnostic test results on the STM for information about how to interpret the test results.

End of steps