Equipment alarms
Among equipment alarms, there are several groups of transceiver-related environment
alarms with escalating thresholds:
- low warning: a Warning alarm indicating that a minor low threshold has been
crossed.
- low alarm: a Critical alarm indicating that a major low threshold has been
crossed.
- high warning: a Warning alarm indicating that a minor high threshold has been
crossed.
- high alarm: a Critical alarm indicating that a major high threshold has been
crossed.
Table 1. 1001 Fan Tray Fault
Alarm ID: |
1001 |
Alarm name: |
Fan Tray Fault |
Description: |
This alarm is raised when the associated fan-tray is
in down/empty/failed/degraded/low-power operational state. The
system may have cooling issues. |
Severity: |
Major |
Probable cause: |
Equipment malfunction |
Remedial action: |
The failed fan unit should be replaced. |
Table 2. 1003 Power Supply Fault
Alarm ID: |
1003 |
Alarm name: |
Power Supply Fault |
Description: |
The alarm is raised when the associated power supply
is not operationally Up. The specified power supply can no longer
supply power to the system. |
Severity: |
Critical |
Probable cause: |
Power problem |
Remedial action: |
Check the status of the power supply. |
Table 3. 1004 Chassis Fault
Alarm ID: |
1004 |
Alarm name: |
Chassis Fault |
Description: |
The alarm is raised when chassis is operationally
down. |
Severity: |
Critical |
Probable cause: |
Equipment malfunction |
Remedial action: |
Chassis Down |
Table 4. 1005 CPM Fault
Alarm ID: |
1005 |
Alarm name: |
CPM Fault |
Description: |
This alarm is generated when the control module is in an
operationally down/empty/failed/degraded/low-power state. |
Severity: |
Critical |
Probable cause: |
Equipment malfunction |
Remedial action: |
Remove the card and reset it. If this does not clear the alarm
then please contact your Nokia support representative for
assistance. |
Table 5. 1006 SFM Fault
Alarm ID: |
1006 |
Alarm name: |
SFM Fault |
Description: |
The alarm is raised when the associated SFM module is in
operationally down/empty/failed/degraded/low-power state. Traffic
could be impacted. |
Severity: |
Critical |
Probable cause: |
Equipment malfunction |
Remedial action: |
The active CPM is at risk of failing to initialize after node
reboot because it cannot access the SFM. Contact Nokia customer
support. |
Table 6. 1007 Line Card Fault
Alarm ID: |
1007 |
Alarm name: |
Line Card Fault |
Description: |
The alarm is raised when the specified line card is in an
operationally down/empty/failed/degraded/low-power state. Traffic is
no longer being transmitted from this line card. |
Severity: |
Major |
Probable cause: |
Equipment malfunction |
Remedial action: |
Ensure that the line card is operationally up. Line card may need
to be replaced. |
Table 7. 1008 Interface Transceiver Down
Alarm ID: |
1008 |
Alarm name: |
Interface Transceiver Down |
Description: |
The alarm is raised when a transceiver goes into the operational
Down state as a result of one of the following possible failures:
- read
- checksum
- unknown
- tx-laser
- connector
|
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Ensure that the transceiver is in good operating condition and is
compatible with the associated interface. The transceiver may need
to be replaced. |
Table 8. 1009 Transceiver Channel High Input Power Warning
Alarm ID: |
1009 |
Alarm name: |
Transceiver Channel High Input Power Warning |
Description: |
The alarm is raised when a transceiver's input power exceeds the
configured Warning threshold for high input power. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 9. 1010 Transceiver Channel High Input Power Alarm
Alarm ID: |
1010 |
Alarm name: |
Transceiver Channel High Input Power Alarm |
Description: |
The alarm is raised when a transceiver's input power exceeds the
configured Alarm threshold for high input power. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 10. 1011 Transceiver Channel Low Input Power Warning
Alarm ID: |
1011 |
Alarm name: |
Transceiver Channel Low Input Power Warning |
Description: |
The alarm is raised when a transceiver's input power is below the
configured Warning threshold for low input power. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 11. 1012 Transceiver Channel Low Input Power Alarm
Alarm ID: |
1012 |
Alarm name: |
Transceiver Channel Low Input Power Alarm |
Description: |
The alarm is raised when a transceiver's input power is below the
configured Alarm threshold for low input power. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 12. 1013 Transceiver Channel High Laser Bias Current Alarm
Alarm ID: |
1013 |
Alarm name: |
Transceiver Channel High Laser Bias Current Alarm |
Description: |
The alarm is raised when a transceiver's high laser bias current
exceeds the configured Alarm threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 13. 1014 Transceiver Channel High Laser Bias Current Warning
Alarm ID: |
1014 |
Alarm name: |
Transceiver Channel High Laser Bias Current Warning |
Description: |
The alarm is raised when a transceiver's high laser bias current
exceeds the configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 14. 1015 Transceiver Channel High Output Power Warning
Alarm ID: |
1015 |
Alarm name: |
Transceiver Channel High Output Power Warning |
Description: |
The alarm is raised when a transceiver's output power exceeds the
configured Warning threshold for high output power. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 15. 1016 Transceiver Channel High Output Power Alarm
Alarm ID: |
1016 |
Alarm name: |
Transceiver Channel High Output Power Alarm |
Description: |
The alarm is raised when a transceiver's output power exceeds the
configured Alarm threshold for high output power. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 16. 1017 Transceiver Channel Low Output Power Warning
Alarm ID: |
1017 |
Alarm name: |
Transceiver Channel Low Output Power Warning |
Description: |
The alarm is raised when a transceiver's output is below the
configured Warning threshold for low output power. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 17. 1018 Transceiver Channel Low Output Power Alarm
Alarm ID: |
1018 |
Alarm name: |
Transceiver Channel Low Output Power Alarm |
Description: |
The alarm is raised when a transceiver's output power is below
configured Alarm threshold for low output power. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 18. 1019 Transceiver Channel Low Laser Bias Current Alarm
Alarm ID: |
1019 |
Alarm name: |
Transceiver Channel Low Laser Bias Current Alarm |
Description: |
The alarm is raised when a transceiver's low laser bias current
is below the configured Alarm threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 19. 1020 Transceiver Channel Low Laser Bias Current Warning
Alarm ID: |
1020 |
Alarm name: |
Transceiver Channel Low Laser Bias Current Warning |
Description: |
The alarm is raised when a transceiver's low laser bias current
is below the configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 20. 1021 Transceiver Low Laser Bias Current Warning
Alarm ID: |
1021 |
Alarm name: |
Transceiver Low Laser Bias Current Warning |
Description: |
The alarm is raised when a transceiver's laser bias current is
below the configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 21. 1022 Transceiver Low Laser Bias Current Alarm
Alarm ID: |
1022 |
Alarm name: |
Transceiver Low Laser Bias Current Alarm |
Description: |
The alarm is raised when a transceiver's laser bias current is
below the configured Alarm threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 22. 1023 Transceiver High Laser Bias Current Warning
Alarm ID: |
1023 |
Alarm name: |
Transceiver High Laser Bias Current Warning |
Description: |
The alarm is raised when a transceiver's laser bias current is
above the configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 23. 1024 Transceiver High Laser Bias Current Alarm
Alarm ID: |
1024 |
Alarm name: |
Transceiver High Laser Bias Current Alarm |
Description: |
The alarm is raised when a transceiver's laser bias current is
above the configured Alarm threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 24. 1025 Transceiver High Input Power Alarm
Alarm ID: |
1025 |
Alarm name: |
Transceiver High Input Power Alarm |
Description: |
The alarm is raised when a transceiver's input power is above the
configured Alarm threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 25. 1026 Transceiver High Input Power Warning
Alarm ID: |
1026 |
Alarm name: |
Transceiver High Input Power Warning |
Description: |
The alarm is raised when a transceiver's input power is above the
configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 26. 1027 Transceiver Low Input Power Warning
Alarm ID: |
1027 |
Alarm name: |
Transceiver Low Input Power Warning |
Description: |
The alarm is raised when a transceiver's input power is below the
configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 27. 1028 Transceiver Low Input Power Alarm
Alarm ID: |
1028 |
Alarm name: |
Transceiver Low Input Power Alarm |
Description: |
The alarm is raised when a transceiver's input power is below the
configured Critical threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 28. 1029 Transceiver High Output Power Alarm
Alarm ID: |
1029 |
Alarm name: |
Transceiver High Output Power Alarm |
Description: |
The alarm is raised when a transceiver's output power above the
configured Alarm threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 29. 1030 Transceiver High Output Power Warning
Alarm ID: |
1030 |
Alarm name: |
Transceiver High Output Power Warning |
Description: |
The alarm is raised when a transceiver's output power is above
the configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 30. 1031 Transceiver Low Output Power Warning
Alarm ID: |
1031 |
Alarm name: |
Transceiver Low Output Power Warning |
Description: |
The alarm is raised when a transceiver's output power is below
the configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 31. 1032 Transceiver Low Output Power Alarm
Alarm ID: |
1032 |
Alarm name: |
Transceiver Low Output Power Alarm |
Description: |
The alarm is raised when a transceiver's output power is below
the configured Critical threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 32. 1033 Transceiver High Voltage Alarm
Alarm ID: |
1033 |
Alarm name: |
Transceiver High Voltage Alarm |
Description: |
The alarm is raised when a transceiver's voltage is above the
configured Alarm threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 33. 1034 Transceiver High Voltage Warning
Alarm ID: |
1034 |
Alarm name: |
Transceiver High Voltage Warning |
Description: |
The alarm is raised when a transceiver's voltage is above the
configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 34. 1035 Transceiver Low Voltage Warning
Alarm ID: |
1035 |
Alarm name: |
Transceiver Low Voltage Warning |
Description: |
The alarm is raised when a transceiver's voltage is below the
configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 35. 1036 Transceiver Low Voltage Alarm
Alarm ID: |
1036 |
Alarm name: |
Transceiver Low Voltage Alarm |
Description: |
The alarm is raised when a transceiver's voltage is below the
configured Critical threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. |
Table 36. 1037 Transceiver High Temperature Alarm
Alarm ID: |
1037 |
Alarm name: |
Transceiver High Temperature Alarm |
Description: |
The alarm is raised when a transceiver's temperature rises above
the configured Alarm threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that the correct cables and transceivers are used on both
ends of the link. Additionally, verify that fans are operating
correctly. |
Table 37. 1038 Transceiver High Temperature Warning
Alarm ID: |
1038 |
Alarm name: |
Transceiver High Temperature Warning |
Description: |
The alarm is raised when a transceiver's temperature is above the
configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that the correct cables and transceivers are used on both
ends of the link. Additionally, verify that fans are operating
correctly. |
Table 38. 1039 Transceiver Low Temperature Warning
Alarm ID: |
1039 |
Alarm name: |
Transceiver Low Temperature Warning |
Description: |
The alarm is raised when a transceiver's temperature is below the
configured Warning threshold. |
Severity: |
Warning |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that correct cables and transceivers are used on both ends
of the link. Additionally, verify fans are operating
correctly. |
Table 39. 1040 Transceiver Low Temperature Alarm
Alarm ID: |
1040 |
Alarm name: |
Transceiver Low Temperature Alarm |
Description: |
The alarm is raised when a transceiver's temperature is below the
configured Critical threshold. |
Severity: |
Critical |
Probable cause: |
DTE DCE TRANSCEIVER ERROR |
Remedial action: |
Verify that the correct cables and transceivers are used on both
ends of the link. Additionally, verify that fans are operating
correctly. |
Communication alarms
Table 40. 4001 LLDP Adjacency Down
Alarm ID: |
4001 |
Alarm name: |
LLDP Adjacency Down |
Description: |
The alarm is raised when the Operational State of an LLDP
adjacency is down. This is because the operational state of local
interface is in a down state. |
Severity: |
Major |
Probable cause: |
DTE DCE Interface Error |
Remedial action: |
The operational state of the interface must be up in order for
the selected adjacency to be up. |
Table 41. 4002 Interface Down
Alarm ID: |
4002 |
Alarm name: |
Interface Down |
Description: |
The alarm is raised when the operational state of interface is
down. |
Severity: |
Critical |
Probable cause: |
DTE DCE Interface Error |
Remedial action: |
The condition exists because the physical interface is down
either because it is administratively disabled, faulty or a cabling
fault has occurred. Ensure that the interface is administratively
up. Check for a poor cable connection to the port or for a faulty
cable/fiber. If neither appears to be the problem run
diagnostics on the port to determine if it is
faulty. |
Table 42. 4003 Subinterface Down
Alarm ID: |
4003 |
Alarm name: |
Subinterface Down |
Description: |
The alarm is raised when the operational state of
subinterface is down. |
Severity: |
Critical |
Probable cause: |
DTE DCE Interface Error |
Remedial action: |
The condition exists because the subinterface is down
either because it is administratively disabled, faulty or a cabling
fault has occurred. Ensure that the subinterface is administratively
up. Check for a poor cable connection to the port or for a faulty
cable/fiber. If neither appears to be the problem run
diagnostics on the port to determine if it is
faulty. |
Table 43. 4004 BGP Adjacency Down
Alarm ID: |
4004 |
Alarm name: |
BGP Adjacency Down |
Description: |
The alarm is raised when the BGP neighbor state
transitions out of the Established state. |
Severity: |
Critical |
Probable cause: |
DTE DCE BGP Error |
Remedial action: |
Verify reachability and BGP parameters match between
BGP neighbors. |
Table 44. 4005 BFD Session Down
Alarm ID: |
4005 |
Alarm name: |
BFD Session Down |
Description: |
The alarm is raised when the BFD session is
operationally down. |
Severity: |
Critical |
Probable cause: |
DTE DCE BFD Error |
Remedial action: |
Verify reachability between BFD neighbors. |
Table 45. 4006 Network Instance Down
Alarm ID: |
4006 |
Alarm name: |
Network Instance Down |
Description: |
The alarm is raised when a network-instance is
down. |
Severity: |
Critical |
Probable cause: |
DTE DCE NET INST DOWN |
Remedial action: |
Verify the configuration of the network-instance. |
Table 46. 4007 Interface LAG Member Down
Alarm ID: |
4007 |
Alarm name: |
Interface LAG Member Down |
Description: |
The alarm is raised when a member of a LAG goes into the
operational down state. |
Severity: |
Warning |
Probable cause: |
DTE DCE INT LAG DOWN |
Remedial action: |
The condition exists because the physical interface
belonging to a LAG is down. The interface could be down because it is
administratively disabled, faulty or a cabling fault has occurred. Do
the following:
- Ensure that the interface is administratively up.
- Check for a poor cable connection to the port or for a faulty
cable/fiber.
- If neither appears to be the problem run diagnostics on the port
to determine if it is faulty.
|
Table 47. 5001 GNMI Connection Fault
Alarm ID: |
5001 |
Alarm name: |
GNMI Connection Fault |
Description: |
GNMI connection to the network element has been lost. |
Severity: |
Major |
Probable cause: |
DTE DCE Interface Error |
Remedial action: |
Check network connectivity to restore GNMI connection. |
Table 48. 5002 Memory Usage Warning
Alarm ID: |
5002 |
Alarm name: |
Memory Usage Warning |
Description: |
The alarm is raised when a device's memory utilization exceeds
75%. |
Severity: |
Warning |
Probable cause: |
SYSTEM WARNING |
Remedial action: |
Check system process memory utilization. |
Note: This alarm indicates that memory utilization
exceeds 75%. This alarm persists even if the Major alarm for
utilization greater than 95% is triggered.
|
Table 49. 5003 Memory Usage Major
Alarm ID: |
5003 |
Alarm name: |
Memory Usage Major |
Description: |
The alarm is raised when a device's memory utilization exceeds
95%. |
Severity: |
Major |
Probable cause: |
SYSTEM WARNING |
Remedial action: |
Check system process memory utilization. |
Note: This alarm indicates that memory utilization
exceeds 95%. Its triggering does not affect the preceding Warning
indicating 75% usage.
|
Table 50. 5004 AAA Server Down
Alarm ID: |
5004 |
Alarm name: |
AAA Server Down |
Description: |
The alarm is raised when a configured AAA server goes into the
operationally down state. |
Severity: |
Major |
Probable cause: |
DTE DCE AAA DOWN |
Remedial action: |
Verify the device configuration and the ability to reach the AAA
server from the device. |
Fabric Services System alarms
Table 51. 6001 Connect Fabric Services System Configuration Failed
Alarm ID: |
6001 |
Alarm name: |
Connect Fabric Services System Configuration Failed |
Description: |
The alarm is raised when changes on Plugin API cannot be
configured on the Fabric Services System. |
Severity: |
Critical |
Probable cause: |
Configuration or customization error |
Remedial action: |
The condition exists because Connect cannot provision the Fabric
Services System with the intended configuration on its Plugin API.
Sanitize the Fabric Services System to resolve this error and
perform audit on Connect. |
Table 52. 6002 Connect Fabric Services System Workload Intent Deploy Failed
Alarm ID: |
6002 |
Alarm name: |
Connect Fabric Services System Workload Intent Deploy
Failed |
Description: |
The alarm is raised when generating configurations and deploying
a workload intent is not possible. |
Severity: |
Critical |
Probable cause: |
Configuration or customization error |
Remedial action: |
The condition exists because Connect cannot deploy the workload
intent on the Fabric Services System. Please make sure the workload
intent is in a deployable state and perform an audit on
Connect. |
Table 53. 6003 Connect Fabric Services System Authentication Failed
Alarm ID: |
6003 |
Alarm name: |
Connect Fabric Services System Authentication Failed |
Description: |
The alarm is raised when Connect cannot authenticate with the
Fabric Services System. |
Severity: |
Critical |
Probable cause: |
Authentication failure |
Remedial action: |
The condition exists because Connect cannot authenticate with the
Fabric Services System. Make sure the Connect configuration is
correct and perform an audit on Connect. |
Table 54. 6004 Connect Plugin Heartbeat Lost
Alarm ID: |
6005 |
Alarm name: |
Connect Plugin Heartbeat Lost |
Description: |
The alarm is raised when Connect no longer detects heartbeat
messages from one of its plugins. |
Severity: |
Critical |
Probable cause: |
CONNECT PLUGIN HEARTBEAT LOST |
Remedial action: |
The condition exists because Connect cannot detect the presence
of one of its plugins. Make sure the plugin is running and actively
issuing heartbeat messages. |
Table 55. 6005 Connect Plugin CMS Authentication Failure
Alarm ID: |
6006 |
Alarm name: |
Connect Plugin CMS Authentication Failure |
Description: |
The alarm is raised when a plugin fails to authenticate with the
CMS for a given deployment. |
Severity: |
Critical |
Probable cause: |
CONNECT PLUGIN CMS AUTHENTICATION FAILURE |
Remedial action: |
The condition exists because a plugin cannot authenticate with
the CMS. Make sure the deployment configuration is correct. |
Table 56. 6007 Connect Plugin Connect Out of Sync with CMS
Alarm ID: |
6007 |
Alarm name: |
Connect Plugin Connect Out of Sync with CMS |
Description: |
The alarm is raised when a plugin re-establishes communication
with Connect, after having registered changes to its deployments
during the period of connection loss. |
Severity: |
Critical |
Probable cause: |
CONNECT PLUGIN CONNECT OUT OF SYNC WITH CMS |
Remedial action: |
The condition exists because the plugin lost connectivity with
Connect for some time. Perform an audit if Connect is out of sync
with the CMS. |
Table 57. 6008 Connect Plugin CMS Connectivity Failure
Alarm ID: |
6008 |
Alarm name: |
Connect Plugin CMS Connectivity Failure |
Description: |
The alarm is raised when a plugin has lost communication with the
CMS, or if there was no connectivity at all for a given
deployment. |
Severity: |
Critical |
Probable cause: |
CONNECT PLUGIN CMS CONNECTIVITY FAILURE |
Remedial action: |
The condition exists because plugin cannot connect to the CMS. Please
make sure you have connectivity between the plugin and the CMS. |