alarms [cleared
] [severity
severity-level] [count
count] [newer-than
days]
A:Dut-A# show system alarms
===============================================================================
Alarms [Critical:1 Major:2 Minor:0 Warning:0 Total:3]
===============================================================================
Index Date/Time Severity Alarm Resource
Details
-------------------------------------------------------------------------------
8 2011/04/01 18:36:43.80 MAJOR 7-2011-1 Power Supply 1
Power supply 1, power lost
7 2011/04/01 18:35:57.00 MAJOR 7-2005-1 Chassis 1
Chassis 1: temperature too high
6 2011/04/01 18:35:24.80 CRITICAL 7-2006-1 Fan 1
Fan 1 failed
===============================================================================
A:Dut-A# show system alarms cleared
===============================================================================
Cleared Alarms [Size:500 Total:5 (not wrapped)]
===============================================================================
Index Date/Time Severity Alarm Resource
Details
-------------------------------------------------------------------------------
5 2011/04/01 18:11:55.00 MAJOR 7-2005-1 Chassis 1
Clear Chassis temperature too high alarm
3 2011/04/01 18:11:54.50 CRITICAL 7-2051-1 Power Supply 1
Clear Power Supply failure
2 2011/04/01 18:11:54.40 CRITICAL 7-2050-1 Power Supply 1
Clear Power Supply failure
4 2011/04/01 18:11:54.10 MINOR 7-2004-1 Fan 1
Clear Fan wrong type failure
1 2011/04/01 18:11:54.00 CRITICAL 7-2007-1 Power Supply 1
Clear Power Supply failure
===============================================================================