Data Communications Channel (DCC)

Provisioning the DCC

To support remote operations over the DCC embedded in the SONET section overhead of the optical signal, the DCC itself must be provisioned as indicated in the following paragraphs.

DCC enable/disable

By default, the DCC is enabled on all optical ports. DCC communications can be enabled or disabled on each port independently.

DCC protection mode

The DCC protection mode is determined by the transmission protection mode assigned to each optical port (per the application parameter). The protection mode can be linear (1+1) identical, or distinct (UPSR). Linear (1+1) identical is the default for the low-speed optical ports. Support is provided for 15 low-speed OC-48 BLSRs.

The following table summarizes the DCC protection modes.

Table 5-4: DCC protection modes

Optical Port Protection Mode

Shelf Slots

Max. Number Simultaneous Optical Ports 1

Max. Number Simultaneous Section DCCs

OC-12/OC-48/OC-192 UPSR

High-speed Main slots

1 pair (2 for OC-192)

1 pair (2 for OC-192)

OC-48/OC-192 BLSR

1 pair (2 for OC-192)

1 pair (2 for OC-192)

OC-12/OC-48/OC-192 Linear (1+1)

1 pair (2 for OC-192)

1 (2 for OC-192)

OC-12/OC-48/OC-192 Bidirectional (1+1)

1 pair (2 for OC-192)

1 (2 for OC-192)

OC-192/OC-48 UPSR

Low-speed Function and Growth slots

20 pairs

20 pairs

OC-192/OC-48 BLSR

15 pairs

15 pairs

OC-192/OC-48 Linear (1+1)

20 pairs

20 pairs

OC-192/OC-48 Bidirectional (1+1)

20 pairs

20 pairs

OC-192/OC-48 0x1 2

20 pairs

20 pairs

OC-48 0x1Sn 2

20 pairs

20 pairs

OC-12 UPSR

60 pairs

60 pairs

OC-12 Linear (1+1)

60 pairs

60 pairs

OC-12 Bidirectional (1+1)

60 pairs

60 pairs

OC-12 0x1 2

60 pairs

60 pairs

OC-12 0x1Sn 2

60 pairs

60 pairs

OC-3 UPSR

80 pairs

80 pairs

OC-3 Linear (1+1)

80 pairs

80 pairs

OC-3 Bidirectional (1+1)

80 pairs

80 pairs

OC-3 0x1 2

80 pairs

80 pairs

OC-3 0x1Sn 2

80 pairs

80 pairs

Notes:
  1. In this table, each optical port counted includes both a transmit and receive fiber.

  2. 0x1 mode is supported with the use of the VLF Main packs. 0x1Sn is supported when non-VLF Mains are used. Since OC-192 tributary packs are only supported with VLF mains, OC-192 0x1Sn is not supported. 0x1 is available on low-speed/tributary packs and VLF high-speed network interface packs.

User side and network side

The operation of each DCC span also depends on one end of the span being designated the "User" side and the other end being designated the "Network" side. The DCC User/Network side assignments are provisionable.

Default User/Network side values
Table 5-5: DCC default values

Default User/Network side values

Optical port protection mode

Slots

DCC AID

BLSR

UPSR

1+1

0x1S1

0x1S2

0x1

High-speed

Main

dcc-m1-{1-x}

User Side

User Side

-

NA

NA

Network Side

dcc-m2-{1-x}

Network Side

Network Side

-

NA

NA

Network Side

dcc-m-{1-x}

-

-

Network Side

NA

NA

-

Low-speed

Function/ Growth

dcc-{a,b,c,d,g}1-{1-x}

Network Side

Network Side

-

Network Side

Network Side 1

Network Side

dcc-{a,b,c,d,g}2-{1-x}

User Side

User Side

-

Network Side 1

Network Side

Network Side

dcc-{a,b,c,d,g}-{1-x}

-

-

Network Side

-

-

-

Notes:
  1. Because DCC is disabled on the corresponding 0x1Sn inactive port, this provisioned value has no effect.

The figure below shows an example of the User and Network side designations for Alcatel-Lucent 1665 DMXs on a high-speed UPSR or BLSR.

Figure 5-5: User/Network side designation on a UPSR/BLSR
User/Network side designation on a UPSR/BLSR

The figure below shows an example of the User and Network side designations for Alcatel-Lucent 1665 DMX on a low-speed UPSR with DDM-2000.

Figure 5-6: User/Network side designation on an OC-3/12 UPSR with DDM-2000
User/Network side designation on an OC-3/12 UPSR with DDM-2000

The figure below shows an example of the User and Network side designations for Alcatel-Lucent 1665 DMX on a low-speed OC-48 BLSR.

Figure 5-7: User/Network side designation on a low-speed OC-48 BLSR
User/Network side designation on a low-speed OC-48 BLSR
DCC compatibility

Alcatel-Lucent 1665 DMX supports the optical interfaces with DCC communications compatibility as shown in the following table. Alcatel-Lucent 1665 DMX supports Section DCC running the OSI protocol stack and IP. The “1+1” entries represent linear and bidirectional (1+1) protected DCC compatibility.

Table 5-6: DCC compatibility

Product

Optical interfaces supported

Alcatel-Lucent 1665 DMX

High-speed main slots

OC-N

Low-speed function

and growth slots

OC-N

192

48

12

3

192

48

12

3

1665 DMX

High-speed

OC-192

UPSR/ BLSR/ 1+1/ 0x1

UPSR/ BLSR/ 1+1/ 0x1

OC-48

UPSR/ BLSR/ 1+1/ 0x1

UPSR/ BLSR/ 1+1/ 0x1Sn/ 0x1

OC-12

UPSR/ 1+1/ 0x1

UPSR/ 1+1/ 0x1Sn/ 0x1

OC-3

UPSR/ 1+1/ 0x1Sn/ 0x1

UPSR/ 1+1/ 0x1Sn/ 0x1

Low- speed

OC-192

UPSR/ BLSR/ 1+1/ 0x1

UPSR/ BLSR/ 1+1/ 0x1

OC-48

UPSR/ BLSR/ 1+1/ 0x1

UPSR/ BLSR/ 1+1/ 0x1Sn/ 0x1

OC-12

UPSR/ 1+1/ 0x1

UPSR/ 1+1/ 0x1Sn/ 0x1

OC-3

UPSR/ 1+1/ 0x1

UPSR/ 1+1/ 0x1Sn/ 0x1

1665 DMXplore

High- speed

OC-3

UPSR/ 1+1

UPSR/ 1+1

1665 DMXtend

High- speed

OC-192

UPSR/ 1+1/ 0x1

OC-48

UPSR/ 1+1/ 0x1

UPSR/ 1+1/ 0x1Sn/ 0x1

OC-12

UPSR/ 1+1/ 0x1

UPSR/ 1+1/ 0x1Sn/ 0x1

OC-3

UPSR/ 1+1/ 0x1Sn/ 0x1

UPSR/ 1+1/ 0x1Sn/ 0x1

Low- speed

OC-48

UPSR/ 1+1/ 0x1

UPSR/ 1+1/ 0x1Sn/ 0x1

OC-12

UPSR/ 1+1/ 0x1

UPSR/ 1+1/ 0x1Sn/ 0x1

OC-3

UPSR/ 1+1/ 0x1

UPSR/ 1+1/ 0x1Sn/ 0x1

DDM- 2000 OC-3

High- speed

OC-12

UPSR

UPSR/ 0x1Sn/ 0x1

OC-3

UPSR/ 1+1

UPSR/ 0x1Sn/ 0x1

Low- speed

OC-3

UPSR/ 1+1

1+1/ 0x1Sn/ 0x1

DDM- 2000 OC-12

High- speed

OC-12

UPSR

UPSR/ 0x1Sn/ 0x1

Low- speed

OC-3

UPSR/ 1+1

1+1/ 0x1Sn/ 0x1

FiberReach

High- speed

OC-12

UPSR

UPSR/ 0x1Sn/ 0x1

OC-3

UPSR/ 1+1

UPSR/ 0x1Sn/ 0x1

FT-2000 ADR

High- speed

OC-48

BLSR

BLSR/ 0x1Sn/ 0x1

Low- speed

OC-12

1+1

1+1/ 0x1Sn/ 0x1

OC-3

1+1

1+1/ 0x1Sn/ 0x1

Wave-Star® TDM 2.5G/10G (2-fiber)

High- speed

OC-48

UPSR/ BLSR

Low- speed

OC-12

UPSR/ 1+1

UPSR/ BLSR/ 1+1/ 0x1Sn/ 0x1

OC-3

UPSR/ 1+1

1+1/ 0x1Sn/ 0x1

WaveStar® Bandwidth Manager, Release 4.0

High- speed

OC-48

UPSR/ BLSR

UPSR/ BLSR/ 1+1/ 0x1Sn/ 0x1

Low- speed

OC-12

UPSR/ 1+1

UPSR/ 1+1/ 0x1Sn/ 0x1

OC-3

UPSR/ 1+1

1+1/ 0x1Sn/ 0x1

Alcatel-Lucent 1675 LambdaUnite MSS

High- speed

OC-192

UPSR/ BLSR/ 1+1

OC-48

UPSR/ BLSR

UPSR/ BLSR/ 0x1Sn/ 0x1

Low- speed

OC-12

UPSR/ 1+1

UPSR/ 1+1/ 0x1Sn/ 0x1

OC-3

UPSR/ 1+1

1+1/ 0x1Sn/ 0x1

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.