epmode |
Port Monitoring Mode may have one of the following values:
-
AUTO (initial value)
-
NMON (not monitored)
-
IS (monitored)
When a port is provisioned in the AUTO state, it will automatically transition to the in-service (IS) state upon detection on the port of a valid input. |
eppm |
Data Port PM Enable. Use the Performance → Prov PM Settings command from the System View menu to set this performance monitoring parameter to one of the following values:
-
Enable (initial value)
-
Disable
This parameter controls whether performance monitoring is enabled or disabled for the specified port. |
tcamd |
TCA Monitoring Mode. This parameter specifies whether performance monitoring Threshold Crossing Alert reporting is enabled or disabled for the port. Use the Performance → Prov PM Settings command from the System View menu to set this performance monitoring parameter to one of the following values:
-
Enable
-
Disable (initial value)
TCA reporting will not begin until tcamd is enabled and port monitoring mode is enabled (eppm = Enabled), and the port is in service (epmode = IS). |
lnrate |
Line Rate. This parameter sets the line rate of the addressed port(s). This parameter is valid when the circuit pack Data Type is set to FC-FICON. Values:
2G rate is only supported on ports 1 and 3. In order to set port 1 to 2G, port 2 must not have a cross-connection and is unused. In order to set port 3 to 2G, port 4 must not have a cross-connection and is unused. |
admin |
Port Administration Control. This parameter is used to enable/disable a port. It will enable/disable all frames to and from a port. Values:
|
rcf |
Remote Client Fail. This parameter enables/disables Remote Client Fail message detection and generation. Values:
This parameter must be enabled at both ends of the circuit in order to function. |
rcf-linkdown |
Remote Client Fail Link Shutdown. When rcf is enabled, this parameter controls link shutdown by Remote Client Fail message reception. Values:
Link Loss Return (LLR) is a feature on some external equipment. External equipment with LLR enabled will stop sending link pulses back to the LNW73/LNW73C if the LNW73/LNW73C has stopped transmitting link pulses to the external equipment due to a link shutdown performed by the Remote Client Fail Link Shutdown feature. Therefore, when the LNW73/LNW73C is connected to equipment that has the Link Loss Return feature enabled, the Remote Client Fail Link Shutdown (rcf-linkdown) option should be disabled to avoid a link shutdown locking problem. Customers planning to use the CSF feature with RCF-Linkdown enabled should disable LLR on the external equipment. |
gfptype |
GFP Encapsulation Type. This parameter sets the User Payload Identifier for GFP Client Frames. This parameter is valid when the circuit pack Data Type is set to FC-FICON. Values:
-
FC - Transparent Fibre Channel (initial value) Used for synchronous full rate
-
FICON - Transparent FICON. Used for synchronous full rate.
-
ASYNC-FC - Asynchronous Transparent Fibre Channel. Used for full and sub-rate rate, supports distance extension. (LNW73/73C only) |
sync_ping |
Synchronous Ping. This parameter enables/disables WAN ping in synchronous GFP. This parameter is valid when portgfptype is set to FC or FICON or when the circuit pack Data Type is set to ESCON. Values:
-
Enable - Enables pinging. Enabling this parameter allows the measurement of the WAN propagation delay. Delay is retrievable by prop_delay in RTRV-DPORT or by Propagation Delay in View → Data → Ethernet/Data/VCG Port.
-
Disable - Disables pinging (initial value). |
compr |
Data Compression. This parameter enables/disables data compression provisioning on an LNW73C port. This parameter is valid when port gfptype is set to async-FC. Values:
-
Enable - Enables data compression. Note: Data Compression is operational if both ends are provisioned for compression, cross-connections are provisioned across the network, and vcgtribs are enabled in both directions. The data compression operational status, compro, will only become enabled when the VCG is operational between both ends (Data Port Status [pstat] value is TRANS [Transparent Operation] or PRT-LNK-INIT [Port Link Initialization]) and the BB Credit settings on the attached Fibre Channel device is set for 8 or fewer credits.
-
Disable - Disables data compression (initial value). |