Use this procedure for examples on provisioning Ethernet services.
This procedure provides references to numerous examples for provisioning Ethernet services. They are intended to be used as reference only to provide you with general Ethernet related provisioning. The examples given may not match your particular configuration. It is impossible to provide examples for all the configurations you may use.
Important!
This procedure assumes that the network system has already been established with all nodes of the network properly equipped and operating for standard SONET transmission.
Use the examples provided in these procedures for establishing service. When removing service follow the reverse of the procedures.
Important!
Under some circumstances, constant pause frames may be transmitted to the link partner when using the LNW63/64/74/87 circuit packs for service. When establishing service, if packets are being transmitted to the port before the circuit has been established with cross-connections and enabled tributaries, stuck pause frames may be sent to the link partner. When disabling service, if enough packets were previously transmitted to the port or continue to be transmitted to the port, stuck pause frames may be sent to the link partner.
Enabling service — To prevent pause frames to the link partner, ensure that no traffic is being sent to the port before the full circuit has been established including all cross-connections made and the tributaries enabled. If this is not possible, use the ed-eport TL1 command admin parameter or the Configuration → Equipment command from the System View menu to provision Port Administration Control to DISABLE on the LAN port before establishing the cross-connections and enabling tributaries. After all cross-connections are made and the tributaries enabled, enable Port Administration Control.
Disabling service — To prevent pause frames to the link partner, remove all traffic from the port first before disabling tributaries and/or deleting cross-connections. If this is not possible, use the ed-eport TL1 command admin parameter or the Configuration → Equipment command from the System View menu to provision Port Administration Control to DISABLE on the LAN port before disabling tributaries or removing cross-connections.
A Alcatel-Lucent 1665 Data Multiplexer equipped with LNW26B/28 OC-48 OLIUs (or functionally equivalent LNW77, LNW121–LNW159, LNW121B–LNW159B OC48 OLIUs) have a capacity limit of 24 STS-1s for Ethernet circuit packs installed in Function slots A, B, or C. Ethernet service assignments are restricted to VCG v1 and v2 on the LNW67/68 2GbE circuit packs when they are installed in Function slots A, B, or C. In slot D or Growth slot, VCGs v1, v2, v3, and v4 may be used.
You must login as either a Privileged or General user to complete this procedure.
Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Obtain the work instructions for the Ethernet service being established.
Be familiar with Ethernet service provisioning or have complete work instructions detailing the particular service being established.
Perform the following steps to provision Ethernet services.
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |