A loss of signal or loss of frame defect has been detected on the protection circuit pack but not on the corresponding active circuit pack.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Minor (MN) |
ASAP Type |
Circuit pack |
AID Type |
Slot |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
FACTERM (Facility termination equipment failure) |
Effect on Service |
NSA |
Alarm Entity Type |
EQPT |
Description |
Protection CP Input fault |
Likely Cause |
Incoming loss of signal, incoming loss of frame defect, or local circuit pack failure. |
Visible Indication |
A flashing Fault LED on the alarmed circuit pack. Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
Action |
Proceed to Procedure 5-116: Clear "PROTN Port Failure/Protection CP Input fault" alarms. |