PROTN DS3 Port Failure

Description

A loss of signal or loss of frame defect has been detected on a protection DS3 port but not on the corresponding active DS3 port.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Not Alarmed (NA)

ASAP Type

DS3 Port

AID Type

DS3 Port

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

PROTN (Protection unit not available)

Effect on Service

NSA

Alarm Entity Type

T3

Description

PROTN DS3 Port Failure

Likely Cause

Incoming loss of signal, incoming loss of frame defect, or local circuit pack failure.

Visible Indication

A flashing Fault LED on the alarmed circuit pack.

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-116: Clear "PROTN Port Failure/Protection CP Input fault" alarms.