AGNE communication failure

Description

The network element cannot establish communication with the designated alarm gateway network element (AGNE), or the AGNE cannot establish communication with a network element in the same alarm group, or the AGNE has lost communication with a network element in the same alarm group.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Major (MJ)

ASAP Type

System

AID Type

Blank

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

PRCDRERR (Procedure error)

Effect on Service

NSA

Alarm Entity Type

COM

Description

AGNE communication failure

Likely Cause

Either the AGNE has not been provisioned or has failed.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively).

Action

Proceed to Procedure 5-3: Clear "AGNE communication failure" alarm.