Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear a Node ID Mismatch alarm.
1 |
Is there a Default K-bytes alarm present?
| ||||||
2 |
From the System View, click the Alarm List button and click Refresh. | ||||||
3 |
Is the Node ID Mismatch alarm still present?
| ||||||
4 |
Important! The port Application parameter of the OC-N ports that interface with the BLSR must be provisioned 2F BLSR. At each node in the BLSR, use View → Equipment to access the required OC-N ports and verify that the port Application parameter is provisioned 2F BLSR. If required, use Configuration → Equipment to access the required OC-N ports and provision the port Application parameter 2F BLSR. | ||||||
5 |
From the System View, select View → Protection and click the Ptn Grp tab, select the appropriate 2F BLSR Protection Group, and click Select. Result: The View Protection window opens. | ||||||
6 |
From the View Protection window, select the Provisionable Parameters tab. | ||||||
7 |
Is Automatic Ring Discovery either enabled or disabled on all nodes in the ring?
| ||||||
8 |
From the System View, select Configuration → Equipment and the Ptn Grp tab, select the appropriate 2F BLSR Protection Group, and click Select. Result: The Configure Equipment window opens. | ||||||
9 |
From the Configure Equipment window, select the provisioning you want for Automatic Ring Discovery on your ring, either Enabled or Disabled. Click Apply and Close. | ||||||
10 |
Repeat Step 8 and Step 9 for all nodes in the ring. | ||||||
11 |
Did you enable Automatic Ring Discovery?
| ||||||
12 |
From the System View, click the Alarm List button and click Refresh. Result: Ring Discovery In Progress condition is present. Wait for the discovery to complete. | ||||||
13 |
From the System View, click the Alarm List button and click Refresh. Result: The Node ID Mismatch alarm and the Ring Discovery In Progress condition are no longer present. | ||||||
14 |
Are there any other alarms listed?
| ||||||
15 |
Select Configuration → Configure Manual Ring Map Result: The Configure Manual Ring Map window opens. | ||||||
16 |
Select the required Ring ID and click Select. Result: The Configure Manual Ring window opens. | ||||||
17 |
Right-click on the node that you wish to modify with a different Node ID. Result: The Manual Ring - Modified Existing Ring Node window opens. | ||||||
18 |
Enter the Modified Node ID and click OK. Result: A confirmation window opens. | ||||||
19 |
Click Yes and then click Apply in the Configure Manual Ring screen. | ||||||
20 |
Select View → Ring Map → Ring Map. Select the required Ring ID and click Select. Verify that the inactive manual ring map was provisioned correctly and click Close. | ||||||
21 |
Select Configuration → Activate Manual Ring Map Result: The Apply Manual Ring Map window opens. | ||||||
22 |
Select the required Ring ID and click Select. Result: A dialog box appears asking you to confirm activating the manual ring map. Click OK. The inactive manual ring map is now activated. | ||||||
23 |
From the System View, select Reports → Remote NE Alarm List. Result: The Remote NE Alarm List appears. | ||||||
24 |
Are there any alarms present on the remote NEs?
| ||||||
25 |
From the System View, click the Alarm List button and click Refresh. Result: The Node ID Mismatch alarm is no longer present. End of steps |