Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear an inc. GE-LAN LOS alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the inc. GE-LAN LOS alarm in the resulting alarm list. | ||||||
2 |
Refer to the Probable Cause column in the alarm list, determine the affected circuit pack, and note the corresponding AID. | ||||||
3 |
Using office records, determine if the LAN port is supposed to be in service.
| ||||||
4 |
Check local fiber/cable connections between the LAN port and the interconnecting equipment for faulty connections or damage and clean/repair/replace as necessary. Reference: Procedure 6-11: Clean optical fibers, dual LC adapters and LC lightguide buildouts (LBOs) | ||||||
5 |
From the System View, click the Alarm List button and click Refresh. | ||||||
6 |
Is the inc. GE-LAN LOS alarm still present?
| ||||||
7 |
Important! A likely cause of the alarm is a failure at the interfacing customer LAN equipment or a problem with fiber/cable between the local LAN port and the interfacing customer LAN equipment. Follow local procedures to isolate and clear the trouble. | ||||||
8 |
From the System View, click the Alarm List button and click Refresh. If the inc. GE-LAN LOS alarm is still present, contact your next level of support. End of steps |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |