Procedure 5-81: Clear "incompatible CP version" alarm

- Overview

This procedure is used to clear a incompatible CP version alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear a incompatible CP versionalarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the incompatible CP version alarm in the resulting alarm list.


2

Refer to the Probable Cause column in the alarm list, determine the affected circuit pack, and note the corresponding slot AID.


3

Important!

An older version of the LNW27 OC-48 OLIU circuit pack was inserted into a slot that contained a newer version of the LNW27 OC-48 OLIU circuit pack.

Select Reports → Equipment Lists → Pack. Select Shelf and click Select to obtain the Circuit Pack List. Observe the correct circuit pack version for the required slot.


4

Replace the old version of circuit pack currently in the required slot with the correct version of the circuit pack.

Reference:

Procedure 6-5: Replace high-speed main OLIU circuit pack


End of steps