Procedure 5-105: Clear "NUT Inconsistent XC Granularity" alarm

- Overview

This procedure is used to clear a NUT Inconsistent XC Granularity alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to identify and clear a NUT Inconsistent XC Granularity alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the NUT Inconsistent XC Granularity alarm in the resulting alarm list and note the corresponding AID.


2

From the System View, select View → Cross-Connections and locate the provisioned cross-connection rate for the alarmed AID.


3

From the System View, select Configuration → Equipment, select the Ptn Grp tab, highlight the 2F BLSR and click Select.

Result:

The Configure Equipment window opens.


4

In Local NUT section of the Configure Equipment window, click the View NUT.

Result:

The View NUT Parameters window opens.


5

In View NUT Parameters window, click the ALL button and locate the alarmed cross-connected AID and all its associated tributaries.


6

Identify any and all inconsistencies in the operational NUT (NUT Type column = OPER) for that cross-connection's tributaries and note the TID for the Requesting Node(s). In the View NUT Parameters and the Provision Parameters for Equipment window, click Close.


7

Log in to a remote NE with the inconsistency, as determined in Step 6.


8

From the System View, select Configuration → Equipment, select the Ptn Grp tab, highlight the 2F BLSR and click Select.

Result:

The Configure Equipment window opens.


9

In Local NUT section of the Configure Equipment window, change the local NUT provisioning for the alarmed cross-connection to match the other tributaries. Then click Apply and Close.

Important!

For NUT Protection Attribute: Protected = PROT, Not Protected = NOTPR, and Temporary Not Protected = TNOTP.


10

Log back into the original NE with the Local NUT Not operational alarm.


11

From the WaveStar® CIT System View, click the Alarm List button and click Refresh. Is the NUT Inconsistent XC Granularity alarm still present?

If...

Then...

Yes

Repeat procedure from Step 7 for another NE with inconstancies.

No

STOP! End of Procedure.


End of steps