Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to identify and clear a NUT Inconsistent XC Granularity alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the NUT Inconsistent XC Granularity alarm in the resulting alarm list and note the corresponding AID. | ||||||
2 |
From the System View, select View → Cross-Connections and locate the provisioned cross-connection rate for the alarmed AID. | ||||||
3 |
From the System View, select Configuration → Equipment, select the Ptn Grp tab, highlight the 2F BLSR and click Select. Result: The Configure Equipment window opens. | ||||||
4 |
In Local NUT section of the Configure Equipment window, click the View NUT. Result: The View NUT Parameters window opens. | ||||||
5 |
In View NUT Parameters window, click the ALL button and locate the alarmed cross-connected AID and all its associated tributaries. | ||||||
6 |
Identify any and all inconsistencies in the operational NUT (NUT Type column = OPER) for that cross-connection's tributaries and note the TID for the Requesting Node(s). In the View NUT Parameters and the Provision Parameters for Equipment window, click Close. | ||||||
7 |
Log in to a remote NE with the inconsistency, as determined in Step 6. | ||||||
8 |
From the System View, select Configuration → Equipment, select the Ptn Grp tab, highlight the 2F BLSR and click Select. Result: The Configure Equipment window opens. | ||||||
9 |
In Local NUT section of the Configure Equipment window, change the local NUT provisioning for the alarmed cross-connection to match the other tributaries. Then click Apply and Close. Important! For NUT Protection Attribute: Protected = PROT, Not Protected = NOTPR, and Temporary Not Protected = TNOTP. | ||||||
10 |
Log back into the original NE with the Local NUT Not operational alarm. | ||||||
11 |
From the WaveStar® CIT System View, click the Alarm List button and click Refresh. Is the NUT Inconsistent XC Granularity alarm still present?
End of steps |