Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to identify and clear a Squelch Data Unavailable alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the Squelch Data Unavailable alarm in the resulting alarm list and note the corresponding AID. | ||||||
2 |
Are DCC-related alarms present in the alarm list?
| ||||||
3 |
From the System View, click the Alarm List button and click Refresh. | ||||||
4 |
Is the Squelch Data Unavailable alarm still present?
| ||||||
5 |
From the System View, select Reports → Remote NE Alarm List. Result: The Remote NE Alarm List window opens. | ||||||
6 |
Are DCC-related alarms present on the remote network elements?
| ||||||
7 |
From the System View, click the Alarm List button and click Refresh. | ||||||
8 |
Is the Squelch Data Unavailable alarm still present?
| ||||||
9 |
From the System View, select View → Rings → Circuit. Result: The View Circuit window opens. | ||||||
10 |
In the View Circuit window, locate missing cross-connections at some point in the circuit and record the TID of that node. Click Close on the View Circuit window. | ||||||
11 |
Log in to a remote NE with the missing or incorrect cross-connection. | ||||||
12 |
From the System View, select Configuration → Cross-Connections to access the Cross-Connection Wizard and provision a new (missing) cross-connection in the circuit or to modify the existing cross-connection. End of steps |