Complete the following steps to clear an Subshelf Configuration Mismatch alarm.
1 |
Important! The local subshelf information (subshelf MAC address and ssconfig.dat file) does not match the subshelf information provisioned on the main shelf. Execute the rtrv-generic and rtrv-subshelf TL1 commands to obtain the local subshelf information. Reference: Alcatel-Lucent 1665 Data Multiplexer (DMX) TL1 Message Details, 365-372-306 | ||||||
2 |
Obtain office records showing the correct local subshelf information. Compare the office records with the local subshelf information obtained in Step 1. | ||||||
3 |
Result: The shelf resets and you are logged off the system. A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing. Reference: Alcatel-Lucent 1665 Data Multiplexer (DMX) TL1 Message Details, 365-372-306 Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session | ||||||
4 |
Important! The provisioned User IDs/passwords must be used to log in to the shelf. When the reset is complete, log back into the shelf. Reference: Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session End of steps |