Procedure 5-135.4: Clear "Subshelf Configuration Mismatch" alarm

Steps

Complete the following steps to clear an Subshelf Configuration Mismatch alarm.

 
1

Important!

The local subshelf information (subshelf MAC address and ssconfig.dat file) does not match the subshelf information provisioned on the main shelf.

Execute the rtrv-generic and rtrv-subshelf TL1 commands to obtain the local subshelf information.

Reference:

Alcatel-Lucent 1665 Data Multiplexer (DMX) TL1 Message Details, 365-372-306


2

Obtain office records showing the correct local subshelf information. Compare the office records with the local subshelf information obtained in Step 1.


3

If the local subshelf information is...

Then...

correct,

Perform the following:

  1. Execute the canc-user TL1 command to log out of the shelf.

  2. Log in to the main shelf and select Configuration → Equipment to access the subshelf information and reprovision the subshelf information correctly.

not correct,

Execute the ed-subshelf TL1 command to reprovision the local subshelf information correctly.

Result:

The shelf resets and you are logged off the system.

A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing.

Reference:

Alcatel-Lucent 1665 Data Multiplexer (DMX) TL1 Message Details, 365-372-306

Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


4

Important!

The provisioned User IDs/passwords must be used to log in to the shelf.

When the reset is complete, log back into the shelf.

Reference:

Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


End of steps