inc. (from fiber) DS3 AIS

Description

DS3 alarm indication signal (AIS) is being received from the far-end DS3 termination.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Not Alarmed (NA)

ASAP Type

DS3 Port

AID Type

DS3 Port

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

AIS-EGR (AIS Detected in Egress direction)

Effect on Service

NSA

Alarm Entity Type

T3

Description

inc. (from fiber) DS3 AIS

Likely Cause

A problem/failure occurred at either the far-end SONET network element or the interfacing customer equipment connected to the far-end SONET network element.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-54: Clear "inc. (from fiber) DSn" alarms.