During the shelf startup procedure, a shelf in a multi-shelf DCS system has detected a corrupt or missing subshelf configuration file (ssconfig.dat) on both NVMs. The Invalid Subshelf Configuration alarm is only reported in the maintenance mode.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Minor (MN) |
AID Type |
Blank |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
DATAFLT (Data Integrity Fault) |
Effect on Service |
NSA |
Alarm Entity Type |
COM |
Description |
Invalid Subshelf Configuration |
Likely Cause |
A shelf in a multi-shelf DCS system has detected a corrupt or missing subshelf configuration file (ssconfig.dat) on both NVMs. |
Visible Indication |
Lighted MN LED on the SYSCTL faceplate. |
Action |
Proceed to Procedure 5-135: Clear "Subshelf-related" alarms/conditions. |