inc. ODU2 LCK

Description

The system has detected a locked (LCK) maintenance signal on an incoming 10G optical channel data unit (ODU2) signal (from the OTU2 port). This indicates that an upstream connection is administratively locked and no signal is passed through.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

SA Default: Critical (CR)

NSA Default: Minor (MN)

ASAP Type

ODU2 Tributary

AID Type

ODU2 Tributary

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

LCK (Lock Signal)

Effect on Service

SA or NSA

Alarm Entity Type

ODU2

Description

inc. ODU2 LCK

Likely Cause

An upstream network element has administratively locked the ODU2 signal from user access while performing a maintenance activity (for example, set-up tests).

SA when the OTU2 is the destination of an OCH cross-connection and at least one of the client ports has a Signal Type of other than STNA. Otherwise, the alarm is reported as NSA.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack.

Action

Proceed to Procedure 5-70: Clear "inc. ODU2 LCK/OCI" alarms.