The system has detected a open connection indication (OCI) maintenance signal on an incoming 10G optical channel data unit (ODU2) signal (from the OTU2 port). This indicates that an upstream connection is not connected.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) SA Default: Critical (CR) NSA Default: Minor (MN) |
ASAP Type |
ODU2 Tributary |
AID Type |
ODU2 Tributary |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
OCI (Open Connection Indication) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
ODU2 |
Description |
inc. ODU2 OCI |
Likely Cause |
An input port is not connected to an output port at an upstream network element (optical cross-connect/switching fabric). SA when the OTU2 is the destination of an OCH cross-connection and at least one of the client ports has a Signal Type of other than STNA. Otherwise, the alarm is reported as NSA. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-70: Clear "inc. ODU2 LCK/OCI" alarms. |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |