There is discontinuity in the circuit path.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Major (MJ) |
ASAP Type |
BLSR Protection Group |
AID Type |
STS-n Ring Channel VT1.5 Ring Channel |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
PAINTGRT (Path Integrity) |
Effect on Service |
NSA |
Alarm Entity Type |
COM |
Description |
Path Integrity Failure |
Likely Cause |
Cross-connect provisioning error (for example, missing pass-through) at some point in the circuit. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
Action |
Proceed to Procedure 5-112: Clear "Path Integrity Failure" alarm. |