Path Integrity Failure

Description

There is discontinuity in the circuit path.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Major (MJ)

ASAP Type

BLSR Protection Group

AID Type

STS-n Ring Channel

VT1.5 Ring Channel

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

PAINTGRT (Path Integrity)

Effect on Service

NSA

Alarm Entity Type

COM

Description

Path Integrity Failure

Likely Cause

Cross-connect provisioning error (for example, missing pass-through) at some point in the circuit.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-112: Clear "Path Integrity Failure" alarm.