BLSR protection switching is temporarily suspended because a valid ring map does not exist or a node does not have a Node ID.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Major (MJ) |
|
ASAP Type |
BLSR Protection Group |
|
AID Type |
BLSR protection group |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
OVRDSW (Override Switch) |
|
Effect on Service |
NSA |
|
Alarm Entity Type |
OC48 OC192 |
|
Description |
Ring Prot Switching Suspended |
|
Likely Cause |
A new node is introduced to the BLSR and does not have a ring map, or the ring map is invalid; BLSR protection switching is disabled. |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
|
Action |
Proceed to Procedure 5-123: Clear "Ring Prot Switching Suspended" alarm. |